CH LAB-Report (R4)
1.0.0 - trial-use
This page is part of the CH LAB-Report (R4) (v1.0.0: STU 1) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Official URL: http://fhir.ch/ig/ch-lab-report/StructureDefinition/ch-lab-report-device-analyzer | Version: 1.0.0 | |||
Active as of 2024-12-18 | Computable Name: ChLabReportDeviceAnalyzer | |||
Copyright/Legal: CC0-1.0 |
Holds Laboratory Analyzer Data.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |
udiCarrier | S | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
deviceIdentifier | 1..1 | string | Mandatory fixed portion of UDI | |
status | S | 0..1 | code | active | inactive | entered-in-error | unknown |
manufacturer | S | 0..1 | string | Name of device manufacturer |
deviceName | S | 0..* | BackboneElement | The name of the device as given by the manufacturer |
type | 0..1 | CodeableConcept | The kind or type of device Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 30234008 | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
udiCarrier | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
deviceIdentifier | Σ | 1..1 | string | Mandatory fixed portion of UDI ele-1: All FHIR elements must have a @value or children |
status | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children |
manufacturer | S | 0..1 | string | Name of device manufacturer ele-1: All FHIR elements must have a @value or children |
deviceName | S | 0..* | BackboneElement | The name of the device as given by the manufacturer ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
name | 1..1 | string | The name of the device ele-1: All FHIR elements must have a @value or children | |
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. ele-1: All FHIR elements must have a @value or children | |
type | 0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 30234008 | |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | |
Device.type | example | Pattern: SNOMED-CT Code 30234008http://hl7.org/fhir/ValueSet/device-type from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | 0..* | Identifier | Instance identifier | |||||
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
udiCarrier | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
deviceIdentifier | Σ | 1..1 | string | Mandatory fixed portion of UDI | ||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
status | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
distinctIdentifier | 0..1 | string | The distinct identification string | |||||
manufacturer | S | 0..1 | string | Name of device manufacturer | ||||
manufactureDate | 0..1 | dateTime | Date when the device was made | |||||
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
lotNumber | 0..1 | string | Lot number of manufacture | |||||
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||
deviceName | S | 0..* | BackboneElement | The name of the device as given by the manufacturer | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
name | 1..1 | string | The name of the device | |||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
modelNumber | 0..1 | string | The model number for the device | |||||
partNumber | 0..1 | string | The part number of the device | |||||
type | 0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices. Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 30234008 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 0..1 | CodeableConcept | The type of the device version | |||||
component | 0..1 | Identifier | A single component of the device version | |||||
value | 1..1 | string | The version text | |||||
property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||
location | 0..1 | Reference(Location) | Where the device is found | |||||
url | 0..1 | uri | Network address to contact device | |||||
note | 0..* | Annotation | Device notes and comments | |||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
parent | 0..1 | Reference(Device) | The parent device | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | example | Pattern: SNOMED-CT Code 30234008http://hl7.org/fhir/ValueSet/device-type from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from Device
Differential View
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |
udiCarrier | S | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
deviceIdentifier | 1..1 | string | Mandatory fixed portion of UDI | |
status | S | 0..1 | code | active | inactive | entered-in-error | unknown |
manufacturer | S | 0..1 | string | Name of device manufacturer |
deviceName | S | 0..* | BackboneElement | The name of the device as given by the manufacturer |
type | 0..1 | CodeableConcept | The kind or type of device Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 30234008 | |
Documentation for this format |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
udiCarrier | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
deviceIdentifier | Σ | 1..1 | string | Mandatory fixed portion of UDI ele-1: All FHIR elements must have a @value or children |
status | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children |
manufacturer | S | 0..1 | string | Name of device manufacturer ele-1: All FHIR elements must have a @value or children |
deviceName | S | 0..* | BackboneElement | The name of the device as given by the manufacturer ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
name | 1..1 | string | The name of the device ele-1: All FHIR elements must have a @value or children | |
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. ele-1: All FHIR elements must have a @value or children | |
type | 0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 30234008 | |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | |
Device.type | example | Pattern: SNOMED-CT Code 30234008http://hl7.org/fhir/ValueSet/device-type from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | 0..* | Identifier | Instance identifier | |||||
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
udiCarrier | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
deviceIdentifier | Σ | 1..1 | string | Mandatory fixed portion of UDI | ||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
status | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
distinctIdentifier | 0..1 | string | The distinct identification string | |||||
manufacturer | S | 0..1 | string | Name of device manufacturer | ||||
manufactureDate | 0..1 | dateTime | Date when the device was made | |||||
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
lotNumber | 0..1 | string | Lot number of manufacture | |||||
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||
deviceName | S | 0..* | BackboneElement | The name of the device as given by the manufacturer | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
name | 1..1 | string | The name of the device | |||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
modelNumber | 0..1 | string | The model number for the device | |||||
partNumber | 0..1 | string | The part number of the device | |||||
type | 0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices. Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 30234008 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 0..1 | CodeableConcept | The type of the device version | |||||
component | 0..1 | Identifier | A single component of the device version | |||||
value | 1..1 | string | The version text | |||||
property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||
location | 0..1 | Reference(Location) | Where the device is found | |||||
url | 0..1 | uri | Network address to contact device | |||||
note | 0..* | Annotation | Device notes and comments | |||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
parent | 0..1 | Reference(Device) | The parent device | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | example | Pattern: SNOMED-CT Code 30234008http://hl7.org/fhir/ValueSet/device-type from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from Device
Other representations of profile: CSV, Excel, Schematron