This page is part of the CH LAB-Order (R4) (v2.0.0-ballot: STU 2 Ballot 1) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
{
"resourceType" : "SpecimenDefinition",
"id" : "single-test-serum-capillary",
"meta" : {
"profile" : [
"http://hl7.org/fhir/uv/order-catalog/StructureDefinition/LabSpecimenDefinition"
]
},
"language" : "en-US",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\" xml:lang=\"en-US\" lang=\"en-US\"><p><b>Generated Narrative: SpecimenDefinition</b><a name=\"single-test-serum-capillary\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource SpecimenDefinition "single-test-serum-capillary" (Language "en-US") </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"http://hl7.org/fhir/uv/order-catalog/2020Sep/StructureDefinition-LabSpecimenDefinition.html\">Laboratory IVD Specimen Definition</a></p></div><p><b>typeCollected</b>: Capillary blood specimen (specimen) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#122554006)</span></p><p><b>collection</b>: Capillary specimen collection (procedure) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#1048003)</span></p><blockquote><p><b>typeTested</b></p><p><b>type</b>: Serum <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v2-0487.html\">specimenType</a>#SER)</span></p><p><b>preference</b>: preferred</p><h3>Containers</h3><table class=\"grid\"><tr><td>-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td>plastic <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#61088005 "Plastic")</span></td><td>Evacuated blood collection tube with clot activator <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#767384004)</span></td><td>red cap <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-container-cap.html\">ContainerCap</a>#red)</span></td><td>red cap plastic tube 2 mL</td><td>2 milliliter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mL = 'mL')</span></td><td>0.5 milliliter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mL = 'mL')</span></td></tr></table><h3>RetentionTimes</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>24</td><td>hour</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table><p><b>rejectionCriterion</b>: blood specimen hemolized <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-rejection-criteria.html\">RejectionCriterion</a>#hemolized)</span>, insufficient quantity of specimen <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-rejection-criteria.html\">RejectionCriterion</a>#insufficient)</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: room temperature or refrigerated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><h3>MaxDurations</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>7</td><td>day</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>d</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: frozen <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><h3>MaxDurations</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>28</td><td>day</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>d</td></tr></table></blockquote></blockquote><blockquote><p><b>typeTested</b></p><p><b>type</b>: Plasma <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v2-0487.html\">specimenType</a>#PLAS)</span></p><p><b>preference</b>: alternate</p><h3>Containers</h3><table class=\"grid\"><tr><td>-</td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td>Evacuated blood collection tube with heparin lithium and gel separator <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#767390000)</span></td><td>green cap <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-container-cap.html\">ContainerCap</a>#green)</span></td><td>green cap plastic tube 2 mL</td><td>2 milliliter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mL = 'mL')</span></td><td>0.5 milliliter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mL = 'mL')</span></td></tr></table><h3>RetentionTimes</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>24</td><td>hour</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table><p><b>rejectionCriterion</b>: blood specimen hemolized <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-rejection-criteria.html\">RejectionCriterion</a>#hemolized)</span>, insufficient quantity of specimen <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-rejection-criteria.html\">RejectionCriterion</a>#insufficient)</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: room temperature or refrigerated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><h3>MaxDurations</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>7</td><td>day</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>d</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: frozen <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><h3>MaxDurations</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>28</td><td>day</td><td><a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html\">Unified Code for Units of Measure (UCUM)</a></td><td>d</td></tr></table></blockquote></blockquote></div>"
},
"typeCollected" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "122554006",
"display" : "Capillary blood specimen (specimen)"
}
]
},
"collection" : [
{
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "1048003",
"display" : "Capillary specimen collection (procedure)"
}
]
}
],
"typeTested" : [
{
"type" : {
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0487",
"code" : "SER",
"display" : "Serum"
}
]
},
"preference" : "preferred",
"container" : {
"material" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "61088005",
"display" : "Plastic"
}
],
"text" : "plastic"
},
"type" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "767384004",
"display" : "Evacuated blood collection tube with clot activator"
}
]
},
"cap" : {
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/container-cap",
"code" : "red"
}
],
"text" : "red cap"
},
"description" : "red cap plastic tube 2 mL",
"capacity" : {
"value" : 2,
"unit" : "milliliter",
"system" : "http://unitsofmeasure.org",
"code" : "mL"
},
"minimumVolumeQuantity" : {
"value" : 0.5,
"unit" : "milliliter",
"system" : "http://unitsofmeasure.org",
"code" : "mL"
}
},
"retentionTime" : {
"value" : 24,
"unit" : "hour",
"system" : "http://unitsofmeasure.org",
"code" : "h"
},
"rejectionCriterion" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/rejection-criteria",
"code" : "hemolized"
}
],
"text" : "blood specimen hemolized"
},
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/rejection-criteria",
"code" : "insufficient"
}
],
"text" : "insufficient quantity of specimen"
}
],
"handling" : [
{
"temperatureQualifier" : {
"text" : "room temperature or refrigerated"
},
"maxDuration" : {
"value" : 7,
"unit" : "day",
"system" : "http://unitsofmeasure.org",
"code" : "d"
}
},
{
"temperatureQualifier" : {
"text" : "frozen"
},
"maxDuration" : {
"value" : 28,
"unit" : "day",
"system" : "http://unitsofmeasure.org",
"code" : "d"
}
}
]
},
{
"type" : {
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0487",
"code" : "PLAS",
"display" : "Plasma"
}
]
},
"preference" : "alternate",
"container" : {
"type" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "767390000",
"display" : "Evacuated blood collection tube with heparin lithium and gel separator"
}
]
},
"cap" : {
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/container-cap",
"code" : "green"
}
],
"text" : "green cap"
},
"description" : "green cap plastic tube 2 mL",
"capacity" : {
"value" : 2,
"unit" : "milliliter",
"system" : "http://unitsofmeasure.org",
"code" : "mL"
},
"minimumVolumeQuantity" : {
"value" : 0.5,
"unit" : "milliliter",
"system" : "http://unitsofmeasure.org",
"code" : "mL"
}
},
"retentionTime" : {
"value" : 24,
"unit" : "hour",
"system" : "http://unitsofmeasure.org",
"code" : "h"
},
"rejectionCriterion" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/rejection-criteria",
"code" : "hemolized"
}
],
"text" : "blood specimen hemolized"
},
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/rejection-criteria",
"code" : "insufficient"
}
],
"text" : "insufficient quantity of specimen"
}
],
"handling" : [
{
"temperatureQualifier" : {
"text" : "room temperature or refrigerated"
},
"maxDuration" : {
"value" : 7,
"unit" : "day",
"system" : "http://unitsofmeasure.org",
"code" : "d"
}
},
{
"temperatureQualifier" : {
"text" : "frozen"
},
"maxDuration" : {
"value" : 28,
"unit" : "day",
"system" : "http://unitsofmeasure.org",
"code" : "d"
}
}
]
}
]
}
IG © 2021+ HL7 Switzerland. Package ch.fhir.ig.ch-lab-order#2.0.0-ballot based on FHIR 4.0.1. Generated 2023-06-29
Links: Table of Contents |
QA Report
| Propose a change