<SpecimenDefinition xmlns="http://hl7.org/fhir">
  <id value="single-test-serum-capillary-fasting"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: SpecimenDefinition</b><a name="single-test-serum-capillary-fasting"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource SpecimenDefinition &quot;single-test-serum-capillary-fasting&quot; </p></div><p><b>typeCollected</b>: Capillary blood specimen <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#122554006)</span></p><p><b>patientPreparation</b>: 12 hour fasting <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span>, At rest <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#263678003)</span></p><p><b>timeAspect</b>: preferrably morning time</p><blockquote><p><b>typeTested</b></p><p><b>type</b>: Capillary blood specimen <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#122554006)</span></p><p><b>preference</b>: preferred</p><h3>Containers</h3><table class="grid"><tr><td>-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td>plastic <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#61088005)</span></td><td>Evacuated blood collection tube with clot activator <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#767384004)</span></td><td>red cap <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-container-cap.html">ContainerCap</a>#red)</span></td><td>red cap plastic tube 2 mL</td><td>2 milliliter<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span></td><td>0.5 milliliter<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span></td></tr></table><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Ambient temperature <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span></p><p><b>temperatureRange</b>: 15-25 °C</p><h3>MaxDurations</h3><table class="grid"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>60</td><td>minute</td><td><a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>min</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Refrigerated temperature <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span></p><p><b>temperatureRange</b>: 2-8 °C</p><h3>MaxDurations</h3><table class="grid"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>8</td><td>hour</td><td><a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table></blockquote></blockquote><blockquote><p><b>typeTested</b></p><p><b>type</b>: Plasma specimen <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#119361006)</span></p><p><b>preference</b>: alternate</p><h3>Containers</h3><table class="grid"><tr><td>-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td>glass <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#32039001)</span></td><td>Evacuated blood collection tube with heparin lithium and gel separator <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#767390000)</span></td><td>green cap <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-container-cap.html">ContainerCap</a>#green)</span></td><td>2 ml<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span></td></tr></table><p><b>rejectionCriterion</b>: insufficient specimen volume <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-rejection-criteria.html">RejectionCriterion</a>#insufficient)</span>, hemolized specimen <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-rejection-criteria.html">RejectionCriterion</a>#hemolized)</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Ambient temperature <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span></p><p><b>temperatureRange</b>: 15-25 °C</p><h3>MaxDurations</h3><table class="grid"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>60</td><td>minute</td><td><a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>min</td></tr></table></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Refrigerated temperature <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span></p><p><b>temperatureRange</b>: 2-8 °C</p><h3>MaxDurations</h3><table class="grid"><tr><td>-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td>*</td><td>8</td><td>hour</td><td><a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table></blockquote></blockquote></div>
  </text>
  <typeCollected>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="122554006"/>
      <display value="Capillary blood specimen"/>
    </coding>
  </typeCollected>
  <patientPreparation>
    <text value="12 hour fasting"/>
  </patientPreparation>
  <patientPreparation>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="263678003"/>
      <display value="At rest"/>
    </coding>
  </patientPreparation>
  <timeAspect value="preferrably morning time"/>
  <typeTested>
    <type>
      <coding>
        <system value="http://snomed.info/sct"/>
        <code value="122554006"/>
        <display value="Capillary blood specimen"/>
      </coding>
    </type>
    <preference value="preferred"/>
    <container>
      <material>
        <coding>
          <system value="http://snomed.info/sct"/>
          <code value="61088005"/>
          <display value="plastic"/>
        </coding>
      </material>
      <type>
        <coding>
          <system value="http://snomed.info/sct"/>
          <code value="767384004"/>
          <display
                   value="Evacuated blood collection tube with clot activator"/>
        </coding>
      </type>
      <cap>
        <coding>
          <system
                  value="http://terminology.hl7.org/CodeSystem/container-cap"/>
          <code value="red"/>
        </coding>
        <text value="red cap"/>
      </cap>
      <description value="red cap plastic tube 2 mL"/>
      <capacity>
        <value value="2"/>
        <unit value="milliliter"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mL"/>
      </capacity>
      <minimumVolumeQuantity>
        <value value="0.5"/>
        <unit value="milliliter"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mL"/>
      </minimumVolumeQuantity>
    </container>
    <handling>
      <temperatureQualifier>
        <text value="Ambient temperature"/>
      </temperatureQualifier>
      <temperatureRange>
        <low>
          <value value="15"/>
          <unit value="°C"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="Cel"/>
        </low>
        <high>
          <value value="25"/>
          <unit value="°C"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="Cel"/>
        </high>
      </temperatureRange>
      <maxDuration>
        <value value="60"/>
        <unit value="minute"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="min"/>
      </maxDuration>
    </handling>
    <handling>
      <temperatureQualifier>
        <text value="Refrigerated temperature"/>
      </temperatureQualifier>
      <temperatureRange>
        <low>
          <value value="2"/>
          <unit value="°C"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="Cel"/>
        </low>
        <high>
          <value value="8"/>
          <unit value="°C"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="Cel"/>
        </high>
      </temperatureRange>
      <maxDuration>
        <value value="8"/>
        <unit value="hour"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="h"/>
      </maxDuration>
    </handling>
  </typeTested>
  <typeTested>
    <type>
      <coding>
        <system value="http://snomed.info/sct"/>
        <code value="119361006"/>
        <display value="Plasma specimen"/>
      </coding>
    </type>
    <preference value="alternate"/>
    <container>
      <material>
        <coding>
          <system value="http://snomed.info/sct"/>
          <code value="32039001"/>
          <display value="glass"/>
        </coding>
      </material>
      <type>
        <coding>
          <system value="http://snomed.info/sct"/>
          <code value="767390000"/>
          <display
                   value="Evacuated blood collection tube with heparin lithium and gel separator"/>
        </coding>
      </type>
      <cap>
        <coding>
          <system
                  value="http://terminology.hl7.org/CodeSystem/container-cap"/>
          <code value="green"/>
          <display value="green cap"/>
        </coding>
      </cap>
      <minimumVolumeQuantity>
        <value value="2"/>
        <unit value="ml"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mL"/>
      </minimumVolumeQuantity>
    </container>
    <rejectionCriterion>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/>
        <code value="insufficient"/>
        <display value="insufficient specimen volume"/>
      </coding>
    </rejectionCriterion>
    <rejectionCriterion>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/>
        <code value="hemolized"/>
        <display value="hemolized specimen"/>
      </coding>
    </rejectionCriterion>
    <handling>
      <temperatureQualifier>
        <text value="Ambient temperature"/>
      </temperatureQualifier>
      <temperatureRange>
        <low>
          <value value="15"/>
          <unit value="°C"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="Cel"/>
        </low>
        <high>
          <value value="25"/>
          <unit value="°C"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="Cel"/>
        </high>
      </temperatureRange>
      <maxDuration>
        <value value="60"/>
        <unit value="minute"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="min"/>
      </maxDuration>
    </handling>
    <handling>
      <temperatureQualifier>
        <text value="Refrigerated temperature"/>
      </temperatureQualifier>
      <temperatureRange>
        <low>
          <value value="2"/>
          <unit value="°C"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="Cel"/>
        </low>
        <high>
          <value value="8"/>
          <unit value="°C"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="Cel"/>
        </high>
      </temperatureRange>
      <maxDuration>
        <value value="8"/>
        <unit value="hour"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="h"/>
      </maxDuration>
    </handling>
  </typeTested>