CH LAB-Order (R4)
2.0.0-ballot - ballot Switzerland flag

This page is part of the CH LAB-Order (R4) (v2.0.0-ballot: STU 2 Ballot 1) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Example ObservationDefinition: observation-serum-potassium

Generated Narrative: ObservationDefinition

Resource ObservationDefinition "observation-serum-potassium" (Language "en-US")

Profile: Laboratory Observation Definition

category: Laboratory (Observation Category Codes#laboratory)

code: Potassium [Moles/volume] in Serum or Plasma (LOINC#2823-3)

permittedDataType: Quantity, string

multipleResultsAllowed: false

method: Ion Selective Electrode (ISE) ()

preferredReportName: Potassium

QuantitativeDetails

-CustomaryUnitUnitDecimalPrecision
*g/L (UCUM#g/L)mmol/L (UCUM#mmol/L)1

qualifiedInterval

category: reference

range: 3.8-5.1

context: Normal Range (Observation Reference Range Meaning Codes#normal)

age: 2-19

qualifiedInterval

category: reference

range: 3.5-5.3

context: Normal Range (Observation Reference Range Meaning Codes#normal)

age: 20-?