Resource Profile: ChLabReportDeviceTestKit

Official URL: http://fhir.ch/ig/ch-lab-report/StructureDefinition/ch-lab-report-device-test-kit Version: 0.1.1
Active as of 2023-12-28 Computable Name: ChLabReportDeviceTestKit

Copyright/Legal: CC0-1.0

Holds Laboratory Test-Kit

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device Device
... definition S0..1Reference(DeviceDefinition)The reference to the definition for the device
... udiCarrier S0..1BackboneElementUnique Device Identifier (UDI) Barcode string
.... deviceIdentifier 1..1stringMandatory fixed portion of UDI
... status S0..1codeactive | inactive | entered-in-error | unknown
... deviceName S0..*BackboneElementThe name of the device as given by the manufacturer
... type 0..1CodeableConceptThe kind or type of device
Required Pattern: At least the following
.... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
..... system1..1uriIdentity of the terminology system
Fixed Value: http://snomed.info/sct
..... code1..1codeSymbol in syntax defined by the system
Fixed Value: 303607000
..... display1..1stringRepresentation defined by the system
Fixed Value: Biomedical equipment (physical object)
... parent S0..1Reference(Device)The parent device

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..*DeviceItem used in healthcare
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... definition S0..1Reference(DeviceDefinition)The reference to the definition for the device
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ1..1stringMandatory fixed portion of UDI
... status ?!SΣ0..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... manufacturer S0..1stringName of device manufacturer
... deviceName S0..*BackboneElementThe name of the device as given by the manufacturer
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... name 1..1stringThe name of the device
.... type 1..1codeudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... type 0..1CodeableConceptThe kind or type of device
Binding: DeviceType (example): Codes to identify medical devices.


Required Pattern: At least the following
.... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
..... system1..1uriIdentity of the terminology system
Fixed Value: http://snomed.info/sct
..... code1..1codeSymbol in syntax defined by the system
Fixed Value: 303607000
..... display1..1stringRepresentation defined by the system
Fixed Value: Biomedical equipment (physical object)
... parent S0..1Reference(Device)The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / Code
Device.statusrequiredFHIRDeviceStatus
Device.deviceName.typerequiredDeviceNameType
Device.typeexamplePattern: SNOMED CT code 303607000("Biomedical equipment (physical object)")

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..*DeviceItem used in healthcare
... id Σ0..1idLogical id of this artifact
... meta Σ0..1MetaMetadata about the resource
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguagesMax Binding
... text 0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... extension 0..*ExtensionAdditional content defined by implementations
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... identifier 0..*IdentifierInstance identifier
... definition S0..1Reference(DeviceDefinition)The reference to the definition for the device
... udiCarrier SΣ0..1BackboneElementUnique Device Identifier (UDI) Barcode string
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ1..1stringMandatory fixed portion of UDI
.... issuer 0..1uriUDI Issuing Organization
.... jurisdiction 0..1uriRegional UDI authority
.... carrierAIDC Σ0..1base64BinaryUDI Machine Readable Barcode String
.... carrierHRF Σ0..1stringUDI Human Readable Barcode String
.... entryType 0..1codebarcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.

... status ?!SΣ0..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..*CodeableConceptonline | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier 0..1stringThe distinct identification string
... manufacturer S0..1stringName of device manufacturer
... manufactureDate 0..1dateTimeDate when the device was made
... expirationDate 0..1dateTimeDate and time of expiry of this device (if applicable)
... lotNumber 0..1stringLot number of manufacture
... serialNumber 0..1stringSerial number assigned by the manufacturer
... deviceName S0..*BackboneElementThe name of the device as given by the manufacturer
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... name 1..1stringThe name of the device
.... type 1..1codeudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 0..1stringThe model number for the device
... partNumber 0..1stringThe part number of the device
... type 0..1CodeableConceptThe kind or type of device
Binding: DeviceType (example): Codes to identify medical devices.


Required Pattern: At least the following
.... id0..1stringUnique id for inter-element referencing
.... extension0..*ExtensionAdditional content defined by implementations
.... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
..... id0..1stringUnique id for inter-element referencing
..... extension0..*ExtensionAdditional content defined by implementations
..... system1..1uriIdentity of the terminology system
Fixed Value: http://snomed.info/sct
..... version0..1stringVersion of the system - if relevant
..... code1..1codeSymbol in syntax defined by the system
Fixed Value: 303607000
..... display1..1stringRepresentation defined by the system
Fixed Value: Biomedical equipment (physical object)
..... userSelected0..1booleanIf this coding was chosen directly by the user
.... text0..1stringPlain text representation of the concept
... specialization 0..*BackboneElementThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... systemType 1..1CodeableConceptThe standard that is used to operate and communicate
.... version 0..1stringThe version of the standard that is used to operate and communicate
... version 0..*BackboneElementThe actual design of the device or software version running on the device
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... type 0..1CodeableConceptThe type of the device version
.... component 0..1IdentifierA single component of the device version
.... value 1..1stringThe version text
... property 0..*BackboneElementThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... type 1..1CodeableConceptCode that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..*QuantityProperty value as a quantity
.... valueCode 0..*CodeableConceptProperty value as a code, e.g., NTP4 (synced to NTP)
... patient 0..1Reference(Patient)Patient to whom Device is affixed
... owner 0..1Reference(Organization)Organization responsible for device
... contact 0..*ContactPointDetails for human/organization for support
... location 0..1Reference(Location)Where the device is found
... url 0..1uriNetwork address to contact device
... note 0..*AnnotationDevice notes and comments
... safety Σ0..*CodeableConceptSafety Characteristics of Device
... parent S0..1Reference(Device)The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / Code
Device.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
Device.udiCarrier.entryTyperequiredUDIEntryType
Device.statusrequiredFHIRDeviceStatus
Device.statusReasonextensibleFHIRDeviceStatusReason
Device.deviceName.typerequiredDeviceNameType
Device.typeexamplePattern: SNOMED CT code 303607000("Biomedical equipment (physical object)")

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

This structure is derived from Device

Summary

Mandatory: 0 element (1 nested mandatory element)
Must-Support: 6 elements

Differential View

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device Device
... definition S0..1Reference(DeviceDefinition)The reference to the definition for the device
... udiCarrier S0..1BackboneElementUnique Device Identifier (UDI) Barcode string
.... deviceIdentifier 1..1stringMandatory fixed portion of UDI
... status S0..1codeactive | inactive | entered-in-error | unknown
... deviceName S0..*BackboneElementThe name of the device as given by the manufacturer
... type 0..1CodeableConceptThe kind or type of device
Required Pattern: At least the following
.... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
..... system1..1uriIdentity of the terminology system
Fixed Value: http://snomed.info/sct
..... code1..1codeSymbol in syntax defined by the system
Fixed Value: 303607000
..... display1..1stringRepresentation defined by the system
Fixed Value: Biomedical equipment (physical object)
... parent S0..1Reference(Device)The parent device

doco Documentation for this format

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..*DeviceItem used in healthcare
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... definition S0..1Reference(DeviceDefinition)The reference to the definition for the device
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ1..1stringMandatory fixed portion of UDI
... status ?!SΣ0..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... manufacturer S0..1stringName of device manufacturer
... deviceName S0..*BackboneElementThe name of the device as given by the manufacturer
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... name 1..1stringThe name of the device
.... type 1..1codeudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... type 0..1CodeableConceptThe kind or type of device
Binding: DeviceType (example): Codes to identify medical devices.


Required Pattern: At least the following
.... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
..... system1..1uriIdentity of the terminology system
Fixed Value: http://snomed.info/sct
..... code1..1codeSymbol in syntax defined by the system
Fixed Value: 303607000
..... display1..1stringRepresentation defined by the system
Fixed Value: Biomedical equipment (physical object)
... parent S0..1Reference(Device)The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / Code
Device.statusrequiredFHIRDeviceStatus
Device.deviceName.typerequiredDeviceNameType
Device.typeexamplePattern: SNOMED CT code 303607000("Biomedical equipment (physical object)")

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..*DeviceItem used in healthcare
... id Σ0..1idLogical id of this artifact
... meta Σ0..1MetaMetadata about the resource
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguagesMax Binding
... text 0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... extension 0..*ExtensionAdditional content defined by implementations
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... identifier 0..*IdentifierInstance identifier
... definition S0..1Reference(DeviceDefinition)The reference to the definition for the device
... udiCarrier SΣ0..1BackboneElementUnique Device Identifier (UDI) Barcode string
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ1..1stringMandatory fixed portion of UDI
.... issuer 0..1uriUDI Issuing Organization
.... jurisdiction 0..1uriRegional UDI authority
.... carrierAIDC Σ0..1base64BinaryUDI Machine Readable Barcode String
.... carrierHRF Σ0..1stringUDI Human Readable Barcode String
.... entryType 0..1codebarcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.

... status ?!SΣ0..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..*CodeableConceptonline | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier 0..1stringThe distinct identification string
... manufacturer S0..1stringName of device manufacturer
... manufactureDate 0..1dateTimeDate when the device was made
... expirationDate 0..1dateTimeDate and time of expiry of this device (if applicable)
... lotNumber 0..1stringLot number of manufacture
... serialNumber 0..1stringSerial number assigned by the manufacturer
... deviceName S0..*BackboneElementThe name of the device as given by the manufacturer
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... name 1..1stringThe name of the device
.... type 1..1codeudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 0..1stringThe model number for the device
... partNumber 0..1stringThe part number of the device
... type 0..1CodeableConceptThe kind or type of device
Binding: DeviceType (example): Codes to identify medical devices.


Required Pattern: At least the following
.... id0..1stringUnique id for inter-element referencing
.... extension0..*ExtensionAdditional content defined by implementations
.... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
..... id0..1stringUnique id for inter-element referencing
..... extension0..*ExtensionAdditional content defined by implementations
..... system1..1uriIdentity of the terminology system
Fixed Value: http://snomed.info/sct
..... version0..1stringVersion of the system - if relevant
..... code1..1codeSymbol in syntax defined by the system
Fixed Value: 303607000
..... display1..1stringRepresentation defined by the system
Fixed Value: Biomedical equipment (physical object)
..... userSelected0..1booleanIf this coding was chosen directly by the user
.... text0..1stringPlain text representation of the concept
... specialization 0..*BackboneElementThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... systemType 1..1CodeableConceptThe standard that is used to operate and communicate
.... version 0..1stringThe version of the standard that is used to operate and communicate
... version 0..*BackboneElementThe actual design of the device or software version running on the device
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... type 0..1CodeableConceptThe type of the device version
.... component 0..1IdentifierA single component of the device version
.... value 1..1stringThe version text
... property 0..*BackboneElementThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... type 1..1CodeableConceptCode that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..*QuantityProperty value as a quantity
.... valueCode 0..*CodeableConceptProperty value as a code, e.g., NTP4 (synced to NTP)
... patient 0..1Reference(Patient)Patient to whom Device is affixed
... owner 0..1Reference(Organization)Organization responsible for device
... contact 0..*ContactPointDetails for human/organization for support
... location 0..1Reference(Location)Where the device is found
... url 0..1uriNetwork address to contact device
... note 0..*AnnotationDevice notes and comments
... safety Σ0..*CodeableConceptSafety Characteristics of Device
... parent S0..1Reference(Device)The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / Code
Device.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
Device.udiCarrier.entryTyperequiredUDIEntryType
Device.statusrequiredFHIRDeviceStatus
Device.statusReasonextensibleFHIRDeviceStatusReason
Device.deviceName.typerequiredDeviceNameType
Device.typeexamplePattern: SNOMED CT code 303607000("Biomedical equipment (physical object)")

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

This structure is derived from Device

Summary

Mandatory: 0 element (1 nested mandatory element)
Must-Support: 6 elements

 

Other representations of profile: CSV, Excel, Schematron