CH LAB-Order (R4)
2.0.0 - trial-use Switzerland flag

This page is part of the CH LAB-Order (R4) (v2.0.0: STU 2) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions

: SpecimenDefinition Blood EDTA - XML Representation

Raw xml | Download



<SpecimenDefinition xmlns="http://hl7.org/fhir">
  <id value="specimen-blood-EDTA"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/order-catalog/StructureDefinition/LabSpecimenDefinition"/>
  </meta>
  <language value="en-US"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml" xml:lang="en-US" lang="en-US"><p><b>Generated Narrative: SpecimenDefinition </b><a name="specimen-blood-EDTA"> </a><a name="hcspecimen-blood-EDTA"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">ResourceSpecimenDefinition &quot;specimen-blood-EDTA&quot;  (Language&quot;en-US&quot;) </p><p style="margin-bottom: 0px">Profile: <a href="http://hl7.org/fhir/uv/order-catalog/2020Sep/StructureDefinition-LabSpecimenDefinition.html">Laboratory IVD Specimen Definition</a></p></div><p><b>typeCollected</b>: Blood venous <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v2-0487.html">specimenType</a>#BLDV)</span></p><p><b>collection</b>: Venipuncture for blood test <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#28520004)</span></p><blockquote><p><b>typeTested</b></p><p><b>type</b>: Whole blood <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v2-0487.html">specimenType</a>#BLD)</span></p><p><b>preference</b>: preferred</p><h3>Containers</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td style="display: none">*</td><td>plastic <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#61088005 &quot;Plastic&quot;)</span></td><td>Blood tube (physical object) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#706049005)</span></td><td>red cap <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.4.0/CodeSystem-container-cap.html">ContainerCap</a>#red)</span></td><td>S-Monovette® EDTA</td><td>4.9 milliliter<span style="background: LightGoldenRodYellow"> (Details: UCUM  codemL = 'mL')</span></td><td>4 milliliter<span style="background: LightGoldenRodYellow"> (Details: UCUM  codemL = 'mL')</span></td></tr></table><h3>RetentionTimes</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style="display: none">*</td><td>2</td><td>hour</td><td><a href="http://terminology.hl7.org/5.4.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table><p><b>rejectionCriterion</b>: blood specimen hemolized <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.4.0/CodeSystem-rejection-criteria.html">RejectionCriterion</a>#hemolized)</span>, insufficient quantity of specimen <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.4.0/CodeSystem-rejection-criteria.html">RejectionCriterion</a>#insufficient)</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: room temperature or refrigerated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span></p><h3>MaxDurations</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Value</b></td><td><b>Unit</b></td><td><b>System</b></td><td><b>Code</b></td></tr><tr><td style="display: none">*</td><td>2</td><td>hour</td><td><a href="http://terminology.hl7.org/5.4.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a></td><td>h</td></tr></table></blockquote></blockquote></div>
  </text>
  <typeCollected>
    <coding>
      <system value="http://terminology.hl7.org/CodeSystem/v2-0487"/>
      <code value="BLDV"/>
      <display value="Blood venous"/>
    </coding>
  </typeCollected>
  <collection>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="28520004"/>
      <display value="Venipuncture for blood test"/>
    </coding>
  </collection>
  <typeTested>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0487"/>
        <code value="BLD"/>
        <display value="Whole blood"/>
      </coding>
    </type>
    <preference value="preferred"/>
    <container>
      <material>
        <coding>
          <system value="http://snomed.info/sct"/>
          <code value="61088005"/>
          <display value="Plastic"/>
        </coding>
        <text value="plastic"/>
      </material>
      <type>
        <coding>
          <system value="http://snomed.info/sct"/>
          <code value="706049005"/>
          <display value="Blood tube (physical object)"/>
        </coding>
      </type>
      <cap>
        <coding>
          <system
                  value="http://terminology.hl7.org/CodeSystem/container-cap"/>
          <code value="red"/>
        </coding>
        <text value="red cap"/>
      </cap>
      <description value="S-Monovette® EDTA"/>
      <capacity>
        <value value="4.9"/>
        <unit value="milliliter"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mL"/>
      </capacity>
      <minimumVolumeQuantity>
        <value value="4"/>
        <unit value="milliliter"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="mL"/>
      </minimumVolumeQuantity>
    </container>
    <retentionTime>
      <value value="2"/>
      <unit value="hour"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="h"/>
    </retentionTime>
    <rejectionCriterion>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/>
        <code value="hemolized"/>
      </coding>
      <text value="blood specimen hemolized"/>
    </rejectionCriterion>
    <rejectionCriterion>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/>
        <code value="insufficient"/>
      </coding>
      <text value="insufficient quantity of specimen"/>
    </rejectionCriterion>
    <handling>
      <temperatureQualifier>
        <text value="room temperature or refrigerated"/>
      </temperatureQualifier>
      <maxDuration>
        <value value="2"/>
        <unit value="hour"/>
        <system value="http://unitsofmeasure.org"/>
        <code value="h"/>
      </maxDuration>
    </handling>
  </typeTested>