CH LAB-Order (R4)
2.0.0 - trial-use Switzerland flag

This page is part of the CH LAB-Order (R4) (v2.0.0: STU 2) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions

: CH LAB-ServiceRequest 0-best-practice Hemoglobin Hematocrit panel - XML Representation

Raw xml | Download



<ServiceRequest xmlns="http://hl7.org/fhir">
  <id value="0-best-practice-service-request-3"/>
  <meta>
    <profile
             value="http://fhir.ch/ig/ch-lab-order/StructureDefinition/ch-lab-order-SR-container"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: ServiceRequest </b><a name="0-best-practice-service-request-3"> </a><a name="hc0-best-practice-service-request-3"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">ResourceServiceRequest &quot;0-best-practice-service-request-3&quot; </p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-ch-lab-order-SR-container.html">CH LAB-Order-SR Container</a></p></div><p><b>identifier</b>: Placer Identifier/123</p><p><b>basedOn</b>: </p><ul><li><a href="ServiceRequest-0-best-practice-service-request-3-hb.html">ServiceRequest/0-best-practice-service-request-3-hb</a></li><li><a href="ServiceRequest-0-best-practice-service-request-3-ht.html">ServiceRequest/0-best-practice-service-request-3-ht</a></li></ul><p><b>status</b>: active</p><p><b>intent</b>: original-order</p><p><b>priority</b>: urgent</p><p><b>code</b>: Hemoglobin and Hematocrit panel - Blood <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a>#24360-0)</span></p><p><b>subject</b>: <a href="Patient-BirgitBlum.html">Patient/BirgitBlum</a> &quot; BLUM&quot;</p><p><b>requester</b>: <a href="PractitionerRole-HansHauserKantonsspital.html">PractitionerRole/HansHauserKantonsspital</a></p><p><b>reasonCode</b>: Anemia screening <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#171201007 &quot;Anemia screening (procedure)&quot;)</span></p></div>
  </text>
  <identifier>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
        <code value="PLAC"/>
        <display value="Placer Identifier"/>
      </coding>
    </type>
    <system value="urn:oid:2.16.756.5.30"/>
    <value value="123"/>
  </identifier>
  <basedOn>🔗 
    <reference value="ServiceRequest/0-best-practice-service-request-3-hb"/>
  </basedOn>
  <basedOn>🔗 
    <reference value="ServiceRequest/0-best-practice-service-request-3-ht"/>
  </basedOn>
  <status value="active"/>
  <intent value="original-order"/>
  <priority value="urgent"/>
  <code>
    <coding>
      <system value="http://loinc.org"/>
      <code value="24360-0"/>
      <display value="Hemoglobin and Hematocrit panel - Blood"/>
    </coding>
  </code>
  <subject>🔗 
    <reference value="Patient/BirgitBlum"/>
  </subject>
  <requester>🔗 
    <reference value="PractitionerRole/HansHauserKantonsspital"/>
  </requester>
  <reasonCode>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="171201007"/>
      <display value="Anemia screening (procedure)"/>
    </coding>
    <text value="Anemia screening"/>
  </reasonCode>
</ServiceRequest>