CH LAB-Order (R4)
3.0.0-ballot - ballot Switzerland flag

This page is part of the CH LAB-Order (R4) (v3.0.0-ballot: STU 3) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions

Example SpecimenDefinition: SpecimenDefinition Urine Spot

Generated Narrative: SpecimenDefinition specimenUrineSpot

Language: en-US

Profile: Laboratory IVD Specimen Definition

typeCollected: Urine

collection: Urine specimen (specimen)

typeTested

type: Urine

preference: Preferred

Containers

-MaterialTypeCapDescriptionCapacityMinimumVolume[x]
*plasticMidstream urine specimen container (physical object)yellow capyellow cap plastic tube 5 mL5 milliliter (Details: UCUM codemL = 'mL')0.5 milliliter (Details: UCUM codemL = 'mL')

RetentionTimes

-ValueUnitSystemCode
*24hourhttp://unitsofmeasure.orgh

rejectionCriterion: insufficient quantity of specimen

handling

temperatureQualifier: 2-8°C

MaxDurations

-ValueUnitSystemCode
*14dayhttp://unitsofmeasure.orgd

handling

temperatureQualifier: -20°

MaxDurations

-ValueUnitSystemCode
*1yearhttp://unitsofmeasure.orgyear