CH EPR FHIR (R4)
4.0.1 - trial-use Switzerland flag

This page is part of the CH EPR FHIR (R4) (v4.0.1: DSTU 4) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: PIXm Patient Identifier Cross-Reference Consumer (client) - TTL Representation

Active as of 2020-07-07

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CapabilityStatement ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "CH.PIXm.Consumer"] ; # 
  fhir:text [
fhir:status [ fhir:v "extensions" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CapabilityStatement CH.PIXm.Consumer</b></p><a name=\"CH.PIXm.Consumer\"> </a><a name=\"hcCH.PIXm.Consumer\"> </a><a name=\"CH.PIXm.Consumer-en-US\"> </a><h2 id=\"title\">PIXm Patient Identifier Cross-Reference Consumer (client)</h2><ul><li>Implementation Guide Version: 4.0.1 </li><li>FHIR Version: 4.0.1 </li><li>Supported Formats: <code>application/fhir+xml</code>, <code>application/fhir+json</code></li><li>Supported Patch Formats: </li><li>Published on: 2020-07-07 </li><li>Published by: eHealth Suisse </li></ul><blockquote class=\"impl-note\"><p><strong>Note to Implementers: FHIR Capabilities</strong></p><p>Any FHIR capability may be 'allowed' by the system unless explicitly marked as 'SHALL NOT'. A few items are marked as MAY in the Implementation Guide to highlight their potential relevance to the use case.</p></blockquote><h2 id=\"rest\">FHIR RESTful Capabilities</h2><div class=\"panel panel-default\"><div class=\"panel-heading\"><h3 id=\"mode1\" class=\"panel-title\">Mode: <code>client</code></h3></div><div class=\"panel-body\"><div><p>PIXm client queries the Patient Identifier Crossreference Manager for the MPI-PID and EPR-SPID [ITI-83].</p>\n</div><div class=\"lead\"><em>Security</em></div><blockquote><div><p>TLS SHALL be used together with IUA basic access token</p>\n</div></blockquote><div class=\"lead\"><em>Summary of System-wide Interactions</em></div></div></div><h3 id=\"resourcesCap1\">Capabilities by Resource/Profile</h3><h4 id=\"resourcesSummary1\">Summary</h4><p>The summary table lists the resources that are part of this configuration, and for each resource it lists:</p><ul><li>The relevant profiles (if any)</li><li>The interactions supported by each resource (<b><span class=\"bg-info\">R</span></b>ead, <b><span class=\"bg-info\">S</span></b>earch, <b><span class=\"bg-info\">U</span></b>pdate, and <b><span class=\"bg-info\">C</span></b>reate, are always shown, while <b><span class=\"bg-info\">VR</span></b>ead, <b><span class=\"bg-info\">P</span></b>atch, <b><span class=\"bg-info\">D</span></b>elete, <b><span class=\"bg-info\">H</span></b>istory on <b><span class=\"bg-info\">I</span></b>nstance, or <b><span class=\"bg-info\">H</span></b>istory on <b><span class=\"bg-info\">T</span></b>ype are only present if at least one of the resources has support for them.</li><li><span>The required, recommended, and some optional search parameters (if any). </span></li><li>The linked resources enabled for <code>_include</code></li><li>The other resources enabled for <code>_revinclude</code></li><li>The operations on the resource (if any)</li></ul><div class=\"table-responsive\"><table class=\"table table-condensed table-hover\"><thead><tr><th><b>Resource Type</b></th><th><b>Profile</b></th><th class=\"text-center\"><b title=\"GET a resource (read interaction)\">R</b></th><th class=\"text-center\"><b title=\"GET all set of resources of the type (search interaction)\">S</b></th><th class=\"text-center\"><b title=\"PUT a new resource version (update interaction)\">U</b></th><th class=\"text-center\"><b title=\"POST a new resource (create interaction)\">C</b></th><th><b title=\"Required and recommended search parameters\">Searches</b></th><th><code><b>_include</b></code></th><th><code><b>_revinclude</b></code></th><th><b>Operations</b></th></tr></thead><tbody><tr><td><a href=\"#Patient1-1\">Patient</a></td><td> </td><td class=\"text-center\"></td><td class=\"text-center\"></td><td class=\"text-center\"></td><td class=\"text-center\"></td><td></td><td/><td/><td><code>$$ihe-pix</code></td></tr></tbody></table></div><hr/><div class=\"panel panel-default\"><div class=\"panel-heading\"><h4 id=\"Patient1-1\" class=\"panel-title\"><span style=\"float: right;\">Resource Conformance: supported </span>Patient</h4></div><div class=\"panel-body\"><div class=\"container\"><div class=\"row\"><div class=\"col-lg-4\"><span class=\"lead\">Core FHIR Resource</span><br/><a href=\"http://hl7.org/fhir/R4/patient.html\">Patient</a></div><div class=\"col-lg-4\"><span class=\"lead\">Reference Policy</span><br/></div><div class=\"col-lg-4\"><span class=\"lead\">Interaction summary</span><br/><ul/></div></div><p/><p/><div class=\"row\"><div class=\"col-12\"><span class=\"lead\">Extended Operations</span><table class=\"table table-condensed table-hover\"><thead><tr><th>Conformance</th><th>Operation</th><th>Documentation</th></tr></thead><tbody><tr><td><b>SHALL</b></td><td><a href=\"OperationDefinition-CH.PIXm.html\">$$ihe-pix</a></td><td><div/></td></tr></tbody></table></div></div></div></div></div></div>"
  ] ; # 
  fhir:url [ fhir:v "http://fhir.ch/ig/ch-epr-fhir/CapabilityStatement/CH.PIXm.Consumer"^^xsd:anyURI] ; # 
  fhir:version [ fhir:v "4.0.1"] ; # 
  fhir:name [ fhir:v "CH_PIXm_Consumer"] ; # 
  fhir:title [ fhir:v "PIXm Patient Identifier Cross-Reference Consumer (client)"] ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:date [ fhir:v "2020-07-07"^^xsd:date] ; # 
  fhir:publisher [ fhir:v "eHealth Suisse"] ; # 
  fhir:contact ( [
fhir:name [ fhir:v "eHealth Suisse" ] ;
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "https://www.e-health-suisse.ch" ]     ] )
  ] ) ; # 
  fhir:description [ fhir:v "The Patient Identifier Cross-reference Consumer Actor CapabilityStatement expresses the requirements that can be utilized while being compliant. - using FHIR R4 - using json or xml encoding - query the $ihe-pix operation"] ; # 
  fhir:jurisdiction ( [
    ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:3166"^^xsd:anyURI ] ;
fhir:code [ fhir:v "CH" ]     ] )
  ] ) ; # 
  fhir:copyright [ fhir:v "CC0-1.0"] ; # 
  fhir:kind [ fhir:v "requirements"] ; # 
  fhir:fhirVersion [ fhir:v "4.0.1"] ; # 
  fhir:format ( [ fhir:v "application/fhir+xml"] [ fhir:v "application/fhir+json"] ) ; # 
  fhir:rest ( [
fhir:mode [ fhir:v "client" ] ;
fhir:documentation [ fhir:v "PIXm client queries the Patient Identifier Crossreference Manager for the MPI-PID and EPR-SPID [ITI-83]." ] ;
fhir:security [
fhir:cors [ fhir:v "false"^^xsd:boolean ] ;
fhir:description [ fhir:v "TLS SHALL be used together with IUA basic access token" ]     ] ;
    ( fhir:resource [
fhir:type [ fhir:v "Patient" ] ;
      ( fhir:operation [
fhir:name [ fhir:v "$ihe-pix" ] ;
fhir:definition [
fhir:v "http://fhir.ch/ig/ch-epr-fhir/OperationDefinition/CH.PIXm"^^xsd:anyURI ;
fhir:link <http://fhir.ch/ig/ch-epr-fhir/OperationDefinition/CH.PIXm>         ]       ] )     ] )
  ] ) . #