Union of http://fhir.ch/ig/ch-emed/StructureDefinition/ch-emed-range and http://fhir.ch/ig/ch-emed/StructureDefinition/ch-emed-range

This is the set of resources that conform to either of the profiles CH EMED Range with Units (http://fhir.ch/ig/ch-emed/StructureDefinition/ch-emed-range) and CH EMED Range with Units (http://fhir.ch/ig/ch-emed/StructureDefinition/ch-emed-range). E.g. what you have to deal with if you get resources conforming to one of them

Structure

NameFlagsCard.TypeDescription & Constraintsdoco
.. Range C0..*Set of values bounded by low and high
ele-1: All FHIR elements must have a @value or children
rng-2: If present, low SHALL have a lower value than high
... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... low C0..1??A fixed quantity (no comparator)
ele-1: All FHIR elements must have a @value or children
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
... high C0..1??A fixed quantity (no comparator)
ele-1: All FHIR elements must have a @value or children
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity

doco Documentation for this format