This is the set of resources that conform to both ChLabReportDeviceTestKit (http://fhir.ch/ig/ch-lab-report/StructureDefinition/ch-lab-report-device-test-kit) and ChLabReportDeviceTestKit (http://fhir.ch/ig/ch-lab-report/StructureDefinition/ch-lab-report-device-test-kit).
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Device | 0..* | Item used in healthcare dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | ||||||
meta | Σ | 0..1 | Meta | Metadata about the resource ele-1: All FHIR elements must have a @value or children | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children | ||||
language | 0..1 | code | Language of the resource content Binding: ?? (preferred): A human language.
ele-1: All FHIR elements must have a @value or children | |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation ele-1: All FHIR elements must have a @value or children | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | ||||
identifier | 0..* | Identifier | Instance identifier ele-1: All FHIR elements must have a @value or children | |||||
definition | S | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device ele-1: All FHIR elements must have a @value or children | ||||
udiCarrier | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string ele-1: All FHIR elements must have a @value or children | ||||
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | ||||
deviceIdentifier | Σ | 1..1 | string | Mandatory fixed portion of UDI ele-1: All FHIR elements must have a @value or children | ||||
issuer | 0..1 | uri | UDI Issuing Organization ele-1: All FHIR elements must have a @value or children | |||||
jurisdiction | 0..1 | uri | Regional UDI authority ele-1: All FHIR elements must have a @value or children | |||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String ele-1: All FHIR elements must have a @value or children | ||||
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String ele-1: All FHIR elements must have a @value or children | ||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: ?? (required): Codes to identify how UDI data was entered. ele-1: All FHIR elements must have a @value or children | |||||
status | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: ?? (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children | ||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: ?? (extensible): The availability status reason of the device. ele-1: All FHIR elements must have a @value or children | |||||
distinctIdentifier | 0..1 | string | The distinct identification string ele-1: All FHIR elements must have a @value or children | |||||
manufacturer | S | 0..1 | string | Name of device manufacturer ele-1: All FHIR elements must have a @value or children | ||||
manufactureDate | 0..1 | dateTime | Date when the device was made ele-1: All FHIR elements must have a @value or children | |||||
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) ele-1: All FHIR elements must have a @value or children | |||||
lotNumber | 0..1 | string | Lot number of manufacture ele-1: All FHIR elements must have a @value or children | |||||
serialNumber | 0..1 | string | Serial number assigned by the manufacturer ele-1: All FHIR elements must have a @value or children | |||||
deviceName | S | 0..* | BackboneElement | The name of the device as given by the manufacturer ele-1: All FHIR elements must have a @value or children | ||||
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | ||||
name | 1..1 | string | The name of the device ele-1: All FHIR elements must have a @value or children | |||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: ?? (required): The type of name the device is referred by. ele-1: All FHIR elements must have a @value or children | |||||
modelNumber | 0..1 | string | The model number for the device ele-1: All FHIR elements must have a @value or children | |||||
partNumber | 0..1 | string | The part number of the device ele-1: All FHIR elements must have a @value or children | |||||
type | 0..1 | CodeableConcept | The kind or type of device Binding: ?? (example): Codes to identify medical devices. ele-1: All FHIR elements must have a @value or children | |||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication ele-1: All FHIR elements must have a @value or children | |||||
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | ||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate ele-1: All FHIR elements must have a @value or children | |||||
version | 0..1 | string | The version of the standard that is used to operate and communicate ele-1: All FHIR elements must have a @value or children | |||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device ele-1: All FHIR elements must have a @value or children | |||||
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | ||||
type | 0..1 | CodeableConcept | The type of the device version ele-1: All FHIR elements must have a @value or children | |||||
component | 0..1 | Identifier | A single component of the device version ele-1: All FHIR elements must have a @value or children | |||||
value | 1..1 | string | The version text ele-1: All FHIR elements must have a @value or children | |||||
property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties ele-1: All FHIR elements must have a @value or children | |||||
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) ele-1: All FHIR elements must have a @value or children | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity ele-1: All FHIR elements must have a @value or children | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) ele-1: All FHIR elements must have a @value or children | |||||
patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed ele-1: All FHIR elements must have a @value or children | |||||
owner | 0..1 | Reference(Organization) | Organization responsible for device ele-1: All FHIR elements must have a @value or children | |||||
contact | 0..* | ContactPoint | Details for human/organization for support ele-1: All FHIR elements must have a @value or children | |||||
location | 0..1 | Reference(Location) | Where the device is found ele-1: All FHIR elements must have a @value or children | |||||
url | 0..1 | uri | Network address to contact device ele-1: All FHIR elements must have a @value or children | |||||
note | 0..* | Annotation | Device notes and comments ele-1: All FHIR elements must have a @value or children | |||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device ele-1: All FHIR elements must have a @value or children | ||||
parent | S | 0..1 | Reference(Device) | The parent device ele-1: All FHIR elements must have a @value or children | ||||
Documentation for this format |