CH LAB-Report (R4)
0.1.1 - draft Switzerland flag

This page is part of the CH LAB-Report (R4) (v0.1.1: DSTU 1 Draft) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Resource Profile: ChLabMeanCorpuscularHemoglobinConcentration - Detailed Descriptions

Active as of 2023-12-28

Definitions for the ch-lab-observation-results-mchc resource profile.

Guidance on how to interpret the contents of this table can be found here

0. Observation
ShortCH Lab Observation Results: Laboratory MCHC
2. Observation.code
Pattern Value&lt;valueCodeableConcept&nbsp;xmlns=&quot;http://hl7.org/fhir&quot;&gt;<br/>&nbsp;&nbsp;&lt;coding&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;system&nbsp;value=&quot;http://loinc.org&quot;/&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;code&nbsp;value=&quot;786-4&quot;/&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;display&nbsp;value=&quot;MCHC&nbsp;[Mass/volume]&nbsp;by&nbsp;Automated&nbsp;count&quot;/&gt;<br/>&nbsp;&nbsp;&lt;/coding&gt;<br/>&lt;/valueCodeableConcept&gt;<br/>

Guidance on how to interpret the contents of this table can be found here

0. Observation
Definition

Measurements and simple assertions made about a patient, device or other subject.

ShortCH Lab Observation Results: Laboratory MCHCMeasurements and simple assertions
Comments

Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

Control0..*
Is Modifierfalse
Summaryfalse
Alternate NamesVital Signs, Measurement, Results, Tests
Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
ch-lab-obs1: The resource should be conform to the corresponding EU LAB profile (conformsTo('http://hl7.eu/fhir/laboratory/StructureDefinition/Observation-resultslab-eu-lab'))
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
2. Observation.implicitRules
Definition

A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

ShortA set of rules under which this content was created
Comments

Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

Control0..1
Typeuri
Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. Observation.extension:observation-instantiates-r5
Slice Nameobservation-instantiates-r5
Definition

This extension implements the R5 instantiates[x] element, to link the ch-lab-result to the observationDefinition r5

Shortinstantiate observationDefinition r5
Control0..1
This element is affected by the following invariants: ele-1
TypeExtension(Observation instantiates an ObservationDefinition) (Extension Type: Reference(ChLabObservationDefinition))
Is Modifierfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
6. Observation.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
Summaryfalse
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
8. Observation.status
Definition

The status of the result value.

Shortregistered | preliminary | final | amended +
Comments

This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

Control1..1
BindingThe codes SHALL be taken from ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1

Codes providing the status of an observation.

Typecode
Is Modifiertrue because This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Requirements

Need to track the status of individual results. Some results are finalized before the whole report is finalized.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
10. Observation.category
Definition

A code that classifies the general type of observation being made. In this profile, fixed to "laboratory".


A code that classifies the general type of observation being made.

ShortClassification of type of observation
Comments

"laboratory" includes laboratory medicine and pathology


In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Control10..*
BindingThe codes SHOULD be taken from ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category

Codes for high level observation categories.

TypeCodeableConcept(Codeable Concept (IPS))
Is Modifierfalse
Summaryfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
SlicingThis element introduces a set of slices on Observation.category. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • pattern @ $this
12. Observation.category:laboratory
Slice Namelaboratory
Definition

A code that classifies the general type of observation being made.

ShortClassification of type of observation
Comments

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Control10..1*
BindingThe codes SHOULD be taken from ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category

Codes for high level observation categories.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Pattern Value&lt;valueCodeableConcept&nbsp;xmlns=&quot;http://hl7.org/fhir&quot;&gt;<br/>&nbsp;&nbsp;&lt;coding&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;system&nbsp;value=&quot;http://terminology.hl7.org/CodeSystem/observation-category&quot;/&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;code&nbsp;value=&quot;laboratory&quot;/&gt;<br/>&nbsp;&nbsp;&lt;/coding&gt;<br/>&lt;/valueCodeableConcept&gt;<br/>
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
14. Observation.category:studyType
Slice NamestudyType
Definition

A code that classifies the general type of observation being made.

ShortThe clinical domain of the laboratory performing the observation (e.g. microbiology, toxicology, chemistry)Classification of type of observation
Comments

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Control0..*
BindingThe codes SHALL be taken from The codes SHOULD be taken from Lab Study Types in Switzerlandhttp://hl7.org/fhir/ValueSet/observation-category
TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
16. Observation.category:specialty
Slice Namespecialty
Definition

A code that classifies the general type of observation being made.

ShortThe way of grouping of the test results into clinically meaningful groups (e.g. liver test; minerals; glucose profiles)Classification of type of observation
Comments

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Control0..*
BindingThe codes SHALL be taken from The codes SHOULD be taken from Laboratory Specialtyhttp://hl7.org/fhir/ValueSet/observation-category
TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
18. Observation.code
Definition

Describes what was observed. Sometimes this is called the observation "name".

ShortType of observation (code / type)
Comments

All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

Control1..1
BindingFor example codes, see LOINCCodeshttp://hl7.org/fhir/ValueSet/observation-codes

Codes identifying names of simple observations.

TypeCodeableConcept
Is Modifierfalse
Summarytrue
Requirements

Knowing what kind of observation is being made is essential to understanding the observation.

Alternate NamesName
Pattern Value&lt;valueCodeableConcept&nbsp;xmlns=&quot;http://hl7.org/fhir&quot;&gt;<br/>&nbsp;&nbsp;&lt;coding&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;system&nbsp;value=&quot;http://loinc.org&quot;/&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;code&nbsp;value=&quot;786-4&quot;/&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;display&nbsp;value=&quot;MCHC&nbsp;[Mass/volume]&nbsp;by&nbsp;Automated&nbsp;count&quot;/&gt;<br/>&nbsp;&nbsp;&lt;/coding&gt;<br/>&lt;/valueCodeableConcept&gt;<br/>
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))

Guidance on how to interpret the contents of this table can be found here

0. Observation
Definition

Measurements and simple assertions made about a patient, device or other subject.

ShortCH Lab Observation Results: Laboratory MCHC
Comments

Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

Control0..*
Is Modifierfalse
Summaryfalse
Alternate NamesVital Signs, Measurement, Results, Tests
Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
ch-lab-obs1: The resource should be conform to the corresponding EU LAB profile (conformsTo('http://hl7.eu/fhir/laboratory/StructureDefinition/Observation-resultslab-eu-lab'))
2. Observation.id
Definition

The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes.

ShortLogical id of this artifact
Comments

The only time that a resource does not have an id is when it is being submitted to the server using a create operation.

Control0..1
Typeid
Is Modifierfalse
Summarytrue
4. Observation.meta
Definition

The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.

ShortMetadata about the resource
Control0..1
TypeMeta
Is Modifierfalse
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
6. Observation.implicitRules
Definition

A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

ShortA set of rules under which this content was created
Comments

Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

Control0..1
Typeuri
Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
8. Observation.language
Definition

The base language in which the resource is written.

ShortLanguage of the resource content
Comments

Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).

Control0..1
BindingThe codes SHOULD be taken from CommonLanguages

A human language.

Additional BindingsPurpose
AllLanguagesMax Binding
Typecode
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
10. Observation.text
Definition

A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety.

ShortText summary of the resource, for human interpretation
Comments

Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.

Control0..1
TypeNarrative
Is Modifierfalse
Summaryfalse
Alternate Namesnarrative, html, xhtml, display
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
12. Observation.contained
Definition

These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope.

ShortContained, inline Resources
Comments

This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.

Control0..*
TypeResource
Is Modifierfalse
Summaryfalse
Alternate Namesinline resources, anonymous resources, contained resources
14. Observation.extension
Definition

An Extension

ShortExtension
Control0..*
TypeExtension
Is Modifierfalse
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
SlicingThis element introduces a set of slices on Observation.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • value @ url
16. Observation.extension:observation-instantiates-r5
Slice Nameobservation-instantiates-r5
Definition

This extension implements the R5 instantiates[x] element, to link the ch-lab-result to the observationDefinition r5

Shortinstantiate observationDefinition r5
Control0..1
This element is affected by the following invariants: ele-1
TypeExtension(Observation instantiates an ObservationDefinition) (Extension Type: Reference(ChLabObservationDefinition))
Is Modifierfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
18. Observation.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
Summaryfalse
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
20. Observation.identifier
Definition

A unique identifier assigned to this observation.

ShortBusiness Identifier for observation
NoteThis is a business identifier, not a resource identifier (see discussion)
Control0..*
TypeIdentifier
Is Modifierfalse
Summarytrue
Requirements

Allows observations to be distinguished and referenced.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
22. Observation.basedOn
Definition

A plan, proposal or order that is fulfilled in whole or in part by this event. For example, a MedicationRequest may require a patient to have laboratory test performed before it is dispensed.

ShortFulfills plan, proposal or order
Control0..*
TypeReference(CarePlan, DeviceRequest, ImmunizationRecommendation, MedicationRequest, NutritionOrder, ServiceRequest)
Is Modifierfalse
Summarytrue
Requirements

Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon.

Alternate NamesFulfills
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
24. Observation.partOf
Definition

A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure.

ShortPart of referenced event
Comments

To link an Observation to an Encounter use encounter. See the Notes below for guidance on referencing another Observation.

Control0..*
TypeReference(MedicationAdministration, MedicationDispense, MedicationStatement, Procedure, Immunization, ImagingStudy)
Is Modifierfalse
Summarytrue
Alternate NamesContainer
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
26. Observation.status
Definition

The status of the result value.

Shortregistered | preliminary | final | amended +
Comments

This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

Control1..1
BindingThe codes SHALL be taken from ObservationStatus

Codes providing the status of an observation.

Typecode
Is Modifiertrue because This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Requirements

Need to track the status of individual results. Some results are finalized before the whole report is finalized.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
28. Observation.category
Definition

A code that classifies the general type of observation being made. In this profile, fixed to "laboratory".

ShortClassification of type of observation
Comments

"laboratory" includes laboratory medicine and pathology

Control1..*
BindingThe codes SHOULD be taken from ObservationCategoryCodes

Codes for high level observation categories.

TypeCodeableConcept(Codeable Concept (IPS))
Is Modifierfalse
Summaryfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
SlicingThis element introduces a set of slices on Observation.category. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • pattern @ $this
30. Observation.category:laboratory
Slice Namelaboratory
Definition

A code that classifies the general type of observation being made.

ShortClassification of type of observation
Comments

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Control1..1
BindingThe codes SHOULD be taken from ObservationCategoryCodes

Codes for high level observation categories.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Pattern Value&lt;valueCodeableConcept&nbsp;xmlns=&quot;http://hl7.org/fhir&quot;&gt;<br/>&nbsp;&nbsp;&lt;coding&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;system&nbsp;value=&quot;http://terminology.hl7.org/CodeSystem/observation-category&quot;/&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;code&nbsp;value=&quot;laboratory&quot;/&gt;<br/>&nbsp;&nbsp;&lt;/coding&gt;<br/>&lt;/valueCodeableConcept&gt;<br/>
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
32. Observation.category:studyType
Slice NamestudyType
Definition

A code that classifies the general type of observation being made.

ShortThe clinical domain of the laboratory performing the observation (e.g. microbiology, toxicology, chemistry)
Comments

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Control0..*
BindingThe codes SHALL be taken from Lab Study Types in Switzerland
TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
34. Observation.category:specialty
Slice Namespecialty
Definition

A code that classifies the general type of observation being made.

ShortThe way of grouping of the test results into clinically meaningful groups (e.g. liver test; minerals; glucose profiles)
Comments

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Control0..*
BindingThe codes SHALL be taken from Laboratory Specialty
TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
36. Observation.code
Definition

Describes what was observed. Sometimes this is called the observation "name".

ShortType of observation (code / type)
Comments

All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

Control1..1
BindingFor example codes, see LOINCCodes

Codes identifying names of simple observations.

TypeCodeableConcept
Is Modifierfalse
Summarytrue
Requirements

Knowing what kind of observation is being made is essential to understanding the observation.

Alternate NamesName
Pattern Value&lt;valueCodeableConcept&nbsp;xmlns=&quot;http://hl7.org/fhir&quot;&gt;<br/>&nbsp;&nbsp;&lt;coding&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;system&nbsp;value=&quot;http://loinc.org&quot;/&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;code&nbsp;value=&quot;786-4&quot;/&gt;<br/>&nbsp;&nbsp;&nbsp;&nbsp;&lt;display&nbsp;value=&quot;MCHC&nbsp;[Mass/volume]&nbsp;by&nbsp;Automated&nbsp;count&quot;/&gt;<br/>&nbsp;&nbsp;&lt;/coding&gt;<br/>&lt;/valueCodeableConcept&gt;<br/>
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
38. Observation.subject
Definition

The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

ShortWho and/or what the observation is about
Comments

One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.

Control0..1
TypeReference(CH Lab Patient)
Is Modifierfalse
Summarytrue
Requirements

Observations have no value if you don't know who or what they're about.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
40. Observation.focus
Definition

The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.

ShortWhat the observation is about, when it is not about the subject of record
Comments

Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use specimen if a reference to a specimen is required. If a code is required instead of a resource use either bodysite for bodysites or the standard extension focusCode.

Control0..*
TypeReference(Resource)
Is Modifierfalse
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
42. Observation.encounter
Definition

The healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made.

ShortHealthcare event during which this observation is made
Comments

This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).

Control0..1
TypeReference(Encounter)
Is Modifierfalse
Summarytrue
Requirements

For some observations it may be important to know the link between an observation and a particular encounter.

Alternate NamesContext
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
44. Observation.effective[x]
Definition

The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

ShortClinically relevant time/time-period for observation
Comments

At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

Control0..1
TypeChoice of: dateTime, Period, Timing, instant
[x] NoteSee Choice of Data Types for further information about how to use [x]
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Requirements

Knowing when an observation was deemed true is important to its relevance as well as determining trends.

Alternate NamesOccurrence
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
46. Observation.issued
Definition

The date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified.

ShortDate/Time this version was made available
Comments

For Observations that don’t require review and verification, it may be the same as the lastUpdated time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the lastUpdated time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.

Control0..1
Typeinstant
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
48. Observation.performer
Definition

Who was responsible for asserting the observed value as "true".

ShortWho is responsible for the observation
Control0..*
TypeReference(CH Lab PractitionerRole, CH Lab Practitioner, CH Core Organization)
Is Modifierfalse
Summarytrue
Requirements

May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
50. Observation.value[x]
Definition

The information determined as a result of making the observation, if the information has a simple value.

ShortActual result
Comments

An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

Control0..1
This element is affected by the following invariants: obs-7
TypeChoice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period
[x] NoteSee Choice of Data Types for further information about how to use [x]
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Requirements

An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
52. Observation.dataAbsentReason
Definition

Provides a reason why the expected value in the element Observation.value[x] is missing.

ShortWhy the result is missing
Comments

Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory".

The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.

Control0..1
This element is affected by the following invariants: obs-6
BindingUnless not suitable, these codes SHALL be taken from DataAbsentReason

Codes specifying why the result (Observation.value[x]) is missing.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

For many results it is necessary to handle exceptional values in measurements.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
54. Observation.interpretation
Definition

A categorical assessment of an observation value. For example, high, low, normal.

ShortHigh, low, normal, etc.
Comments

Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

Control0..*
BindingUnless not suitable, these codes SHALL be taken from ObservationInterpretationCodes

Codes identifying interpretations of observations.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

Alternate NamesAbnormal Flag
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
56. Observation.note
Definition

Comments about the observation or the results.

ShortComments about the observation
Comments

May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.

Control0..*
TypeAnnotation
Is Modifierfalse
Summaryfalse
Requirements

Need to be able to provide free text additional information.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
58. Observation.bodySite
Definition

Indicates the site on the subject's body where the observation was made (i.e. the target site).

ShortObserved body part
Comments

Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component.

If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension bodySite.

Control0..1
BindingFor example codes, see SNOMEDCTBodyStructures

Codes describing anatomical locations. May include laterality.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
60. Observation.method
Definition

Indicates the mechanism used to perform the observation.

ShortHow it was done
Comments

Only used if not implicit in code for Observation.code.

Control0..1
BindingFor example codes, see ObservationMethods

Methods for simple observations.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
62. Observation.specimen
Definition

The specimen that was used when this observation was made.

ShortSpecimen used for this observation
Comments

Should only be used if not implicit in code found in Observation.code. Observations are not made on specimens themselves; they are made on a subject, but in many cases by the means of a specimen. Note that although specimens are often involved, they are not always tracked and reported explicitly. Also note that observation resources may be used in contexts that track the specimen explicitly (e.g. Diagnostic Report).

Control0..1
TypeReference(CH Lab Specimen: Laboratory)
Is Modifierfalse
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
64. Observation.device
Definition

The device used to generate the observation data.

Short(Measurement) Device
Comments

Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant.

Control0..1
TypeReference(Device, DeviceMetric)
Is Modifierfalse
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
66. Observation.referenceRange
Definition

Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two referenceRange elements would be used.

ShortProvides guide for interpretation
Comments

Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

Control0..*
TypeBackboneElement
Is Modifierfalse
Summaryfalse
Requirements

Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
68. Observation.referenceRange.id
Definition

Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

ShortUnique id for inter-element referencing
Control0..1
Typestring
Is Modifierfalse
XML FormatIn the XML format, this property is represented as an attribute.
Summaryfalse
70. Observation.referenceRange.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

ShortAdditional content defined by implementations
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifierfalse
Summaryfalse
Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
72. Observation.referenceRange.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
74. Observation.referenceRange.low
Definition

The value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3).

ShortLow Range, if relevant
Control0..1
This element is affected by the following invariants: obs-3
TypeQuantity(SimpleQuantity)
Is Modifierfalse
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
76. Observation.referenceRange.high
Definition

The value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3).

ShortHigh Range, if relevant
Control0..1
This element is affected by the following invariants: obs-3
TypeQuantity(SimpleQuantity)
Is Modifierfalse
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
78. Observation.referenceRange.type
Definition

Codes to indicate the what part of the targeted reference population it applies to. For example, the normal or therapeutic range.

ShortReference range qualifier
Comments

This SHOULD be populated if there is more than one range. If this element is not present then the normal range is assumed.

Control0..1
BindingThe codes SHOULD be taken from ObservationReferenceRangeMeaningCodes

Code for the meaning of a reference range.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, etc., - for proper interpretation.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
80. Observation.referenceRange.appliesTo
Definition

Codes to indicate the target population this reference range applies to. For example, a reference range may be based on the normal population or a particular sex or race. Multiple appliesTo are interpreted as an "AND" of the target populations. For example, to represent a target population of African American females, both a code of female and a code for African American would be used.

ShortReference range population
Comments

This SHOULD be populated if there is more than one range. If this element is not present then the normal population is assumed.

Control0..*
BindingFor example codes, see ObservationReferenceRangeAppliesToCodes

Codes identifying the population the reference range applies to.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

Need to be able to identify the target population for proper interpretation.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
82. Observation.referenceRange.age
Definition

The age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so.

ShortApplicable age range, if relevant
Control0..1
TypeRange
Is Modifierfalse
Summaryfalse
Requirements

Some analytes vary greatly over age.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
84. Observation.referenceRange.text
Definition

Text based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals".

ShortText based reference range in an observation
Control0..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
86. Observation.hasMember
Definition

This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

ShortRelated resource that belongs to the Observation group
Comments

When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

Control0..*
TypeReference(Observation, QuestionnaireResponse, MolecularSequence)
Is Modifierfalse
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
88. Observation.derivedFrom
Definition

The target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image.

ShortRelated measurements the observation is made from
Comments

All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below.

Control0..*
TypeReference(DocumentReference, ImagingStudy, Media, QuestionnaireResponse, Observation, MolecularSequence)
Is Modifierfalse
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
90. Observation.component
Definition

Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

ShortComponent results
Comments

For a discussion on the ways Observations can be assembled in groups together see Notes below.

Control0..*
TypeBackboneElement
Is Modifierfalse
Summarytrue
Requirements

Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
92. Observation.component.id
Definition

Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

ShortUnique id for inter-element referencing
Control0..1
Typestring
Is Modifierfalse
XML FormatIn the XML format, this property is represented as an attribute.
Summaryfalse
94. Observation.component.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

ShortAdditional content defined by implementations
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifierfalse
Summaryfalse
Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
96. Observation.component.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
98. Observation.component.code
Definition

Describes what was observed. Sometimes this is called the observation "code".

ShortType of component observation (code / type)
Comments

All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

Control1..1
BindingFor example codes, see LOINCCodes

Codes identifying names of simple observations.

TypeCodeableConcept
Is Modifierfalse
Summarytrue
Requirements

Knowing what kind of observation is being made is essential to understanding the observation.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
100. Observation.component.value[x]
Definition

The information determined as a result of making the observation, if the information has a simple value.

ShortActual component result
Comments

Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

Control0..1
TypeChoice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period
[x] NoteSee Choice of Data Types for further information about how to use [x]
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Requirements

An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
102. Observation.component.dataAbsentReason
Definition

Provides a reason why the expected value in the element Observation.component.value[x] is missing.

ShortWhy the component result is missing
Comments

"Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

Control0..1
This element is affected by the following invariants: obs-6
BindingUnless not suitable, these codes SHALL be taken from DataAbsentReason

Codes specifying why the result (Observation.value[x]) is missing.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

For many results it is necessary to handle exceptional values in measurements.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
104. Observation.component.interpretation
Definition

A categorical assessment of an observation value. For example, high, low, normal.

ShortHigh, low, normal, etc.
Comments

Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

Control0..*
BindingUnless not suitable, these codes SHALL be taken from ObservationInterpretationCodes

Codes identifying interpretations of observations.

TypeCodeableConcept
Is Modifierfalse
Summaryfalse
Requirements

For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

Alternate NamesAbnormal Flag
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
106. Observation.component.referenceRange
Definition

Guidance on how to interpret the value by comparison to a normal or recommended range.

ShortProvides guide for interpretation of component result
Comments

Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

Control0..*
TypeSee ttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
Is Modifierfalse
Summaryfalse
Requirements

Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))